When evaluating sterilizers, you should consider the devices your facility sterilizes most frequently. The STERRAD® Systems brand has the most Medical Device Manufacturer (MDM) IFU endorsements for low-temperature sterilization.
Although they may have some similarities, other sterilization systems do not have the same sterilization claims and features as STERRAD® Systems. Use this guide to make notes about how other systems you are considering compare to STERRAD® Systems. Contact your ASP representative regarding trade-in opportunities and promotional pricing to upgrade to STERRAD® Systems.
Compare Systems | ||||
---|---|---|---|---|
SEE DETAILS | SEE DETAILS | SEE DETAILS | ||
GENERAL SYSTEM INFORMATION | ||||
Brand with the most IFU endorsements for low temperature sterilization. | YES | YES | YES | |
Hydrogen peroxide gas plasma technology - plasma phase breaks down H202 in the chamber rather than simply venting it through a filter | YES | YES | YES | |
Proprietary H202 monitors measure sterilant concentration during cycle | YES | YES | NO | |
Sterilziation will cancel if instruments are not dry as required by multi-society guidelines | YES | YES | YES | |
Shelf Dimensions | Both shelves: 17 in x 28 in |
Both shelves: 12.3 in x 23.6 in |
Top: 17 in x 28 in Bottom: 30 in x 13 in |
|
Approx. Cycle Times (including aeration, if required) | 60 minutes - DUO 42 minutes - FLEX 47 minutes - STANDARD 24 minutes - EXPRESS |
28 minutes - STANDARD 38 minutes - ADVANCED |
55 minutes | |
Instrument Tracking Software (ITS) connectivity | YES | YES | NO | |
Easy-to-handle sterilant cassette | YES | YES | YES | |
Byproducts - water vapor and oxygen | YES | YES | YES | |
Weekly leak test required | NO | NO | NO | |
Ergonomic footpad | YES | NO | NO | |
Easy-to-load thermal printer - no ribbon required | YES | YES | N0 | |
Stores short-term cycle data and allows for customized record keeping | YES | YES | NO | |
STERILIZATION CAPABILITIES | ||||
Single-channel stainless steel lumens | ≥0.7 mm x ≤ 500 mm | ≥1 mm x ≤ 500 mm | ≥1 mm x ≤ 125 mm ≥2 mm x ≤ 250 mm ≥3 mm x ≤ 400 mm |
|
Single-channel flexible scope lumens (PE/PTFE) | ≥1 mm x ≤ 875 mm (DUO Cycle) | ≥1 mm x ≤ 850 mm | OUTSIDE THE US ONLY | |
da Vinci® 3-D endoscopes | YES (EXPRESS Cycle)* | NO | YES | |
Indications for Use includes metal, non-metal, heat- and moisture-sensitive devices | YES | YES | YES | |
Supported by the online STERRAD® Sterility Guide, listing 12,000+ devices within STERRAD® Systems sterility claims and validated by Device Manufacturers (MDMs) | YES | YES | YES | |
*Valid only for the DUO cycle | ||||
EDUCATION & SUPPORT | ||||
Clinical Education Consultants available before and after installation | YES | YES | YES | |
Purchase includes installation, all validation materials, in-servicing, a 1-year warranty and planned maintenance for the first year | YES | YES | YES | |
Service Contracts: Various Options Available | YES | YES | YES | |
Service consistently ranked high in third party customer surveys including MD Buyline | YES | YES | YES | |
Biomedical Training Available | YES | YES | YES | |
INSTALLATION REQUIREMENTS | ||||
Electrical requirements | 208 VAC, 60 Hz, 30 Amp |
108 VAC, 20 Amp | 208 VAC, 60 Hz, 20 Amp | |
Water required | NO | NO | NO | |
Venting/vent line required | NO | NO | NO | |
Drainage required | NO | NO | NO | |
Gas tank or oxygen tank required | NO | NO | NO | |
Abator or aeration required | NO | NO | NO |