Our systems are based
on the following major items: |
|
|
|
|
1. |
sample take-off probes
for installation on process lines |
|
2. |
sample pre-conditioning
units (temperature and pressure control) |
|
3. |
fast-loop systems
and pumping facilities, engineered in order to provide correct hold-up
time depending |
|
|
on analysis cycle
time |
|
4. |
sample conditioning
systems, properly designed in order to provide sample to analyzers
at suitable flow, |
|
|
temperature , pressure
and filtration values |
|
5. |
PLC based safety control
system |
|
6. |
sample recovery system
to collect spent samples and pump back to process lines |
|
7. |
analyzer shelters
fully equipped with: |
|
|
- Heating Ventilating
and Air Conditioning System |
|
|
- Power distribution
systems |
|
|
- Lightning |
|
|
- Grounding |
|
|
- Safety devices and
Gas Monitoring Systems |
|
|
- Utilities headers |
|
|
- on-line analyzers
such as: Gaschromatographs, Flash Point, Freeze Point, Pour Point,
Viscosity, Vapour |
|
|
pressure, TOC, Moisture,
Density, Chemical composition, Physical properties, NIR, FTIR, Sulphur
etc. |
|
|
|
|
TECHNICAL FEATURES |
|
|
|
|
ATEC analysis system
is based on the following main features: |
|
|
|
|
1. |
Shelter structure and
covering |
|
|
|
|
|
The structure upon
which the walls roof and the floorboard are mounted forms a single
frame and will be |
|
|
sized in order to
permit hoisting, transport and positioning, without any damage or
permanent |
|
|
deformation. |
|
|
|
|
|
Walls and roofs are
sandwich type with inside/outside panels in painted galvanized steel
plate or AISI |
|
|
304/316 steel plate.
Thermal insulation is guaranteed by 50 mm. fire retardant expanded
polyurethan |
|
|
sheets (density 40
Kg/mc and thermal conductivity 0,40 Kcal/h mq. °C). |
|
|
|
|
|
The roof is properly
designed and constructed to support the combined weight of two men
without |
|
|
causing any permanent
deformation. The roof design includes also detachable side overhangs
for |
|
|
sampling systems protection
and lifting eyebolts hooked to the base frame. |
|
|
|
|
|
The floor made in
chequered steel plate, includes drainage well. |
|
|
|
|
|
Shelter are equipped
with opening outwards doors (main/emergency) with unbreaking window.
All locks, |
|
|
handles, hings and
pins are based on weather resistant materials. |
|
|
|
|
2. |
Painting |
|
|
|
|
|
Where applicable,
painting is performed according to our procedure: |
|
|
- one hand of WASHPRIMER
epoxy paint type |
|
|
- two hands of FINISHING
epoxy paint type. |
|
|
|
|
|
Paint characteristics: |
|
|
- acid resistant |
|
|
- corrosive resistant |
|
|
- fungus resistant |
|
|
|
|
|
Thickness of the dry
paint film 70-80 microns as minimun. |
|
|
|
|
3. |
Electrical |
|
|
|
|
|
ATEC is structured
to supply equipment suitable for installation in explosion hazardous
area according to |
|
|
CENELEC rules. |
|
|
|
|
|
Cables carrying different
signals types arel adeguately set apart to ensure integrity and prevent
any . |
|
|
form of interference.
Cable routing is arranged within the analyzer shelter according to
the best |
|
|
engineering practice. |
|
|
|
|
|
Power distribution
panels are provided with individual insulation circuit for each item
complete with |
|
|
automatic circuit
breakers and lamps; each electric motors are protected by a thermal
cutout. |
|
|
|
|
|
J-boxes for alarm,
analog and digital signal, serial link each one equipped with terminal
strip considering |
|
|
adequate spare are
installed outside the shelter. |
|
|
|
|
4. |
Lighting system |
|
|
|
|
|
Internal and external
systems are usually based on rapid start fluorescent type lamps using
EEx-d lamp |
|
|
holders. |
|
|
|
|
5. |
Utilities |
|
|
|
|
|
Utilities design is
strictly depending on analysis application and plant availability. |
|
|
|
|
|
ATEC packages are
engineered according to the following guidelines: |
|
|
- headers installed
outside on the same side of sampling systems; |
|
|
- instrument air and
water headers equipped with on line filtration unit; |
|
|
- each utility take-off
will provided with an isolating valve; |
|
|
- vent header equipped
with flame arrestor |
|
|
- steam and condensate
headers will be thermal insulated. |
|
|
|
|
6. |
Air conditioning and
ventilating system |
|
|
|
|
|
Our application includes the supply of a redundant air conditioning
and pressurizing system manufactured
|
|
|
by ATEC. |
|
|
|
|
|
Further technical
details on this item are available on dedicated ATEC brochure |
|
|
|
|
7. |
Safety devices |
|
|
|
|
|
Our standard package
includes the supply of a complete alarm control system based on the
following |
|
|
equipment : |
|
|
- Differential pressure
switch, to give alarm for low pressurization inside the shelter. |
|
|
- Flow switches (one
for each ventilation fan) |
|
|
- Combustible gas
monitors with the ancillary control unit |
|
|
- Toxic gas monitor
with the ancillary control unit |
|
|
- Temperature switch
for high temperature inside the shelter |
|
|
|
|
|
Contacts coming from
the above apparatus are managed by shelter alarm control system based
on PLC |
|
|
technology. |
|
|
|
|
|
The shelter are equipped
with alarm annunciators according to ISA-1 standards both assembled
in EExd |
|
|
enclosure according
to CENELEC, for hazardous area. |
|
|
|
|
|
The alarm contacts
available to control room are indipendent and insulated, Normally
Open (NO) fail safe |
|
|
type with alarm condition
at the de-energized state. |
|
|
|
|
8. |
Sample handling systems |
|
|
|
|
|
Sample pre-conditioning,
fast loop and sample conditioning/validation units are designed and
engineered |
|
|
according to Customer
specifictaions, process fluid characteristics and hold-up time in
order to provide |
|
|
significant sample
to analyzer. |
|
|
|
|
|
Standard liquid calibration/validation
facilities include sample drum with nitrogen driven piston, level
|
|
|
control, double block
& bleed stream selection, portable sample collection bottle with
quick coupling. |
|
|
|
|
|
Components are selected
on the basis of high performance and material compatibility (stainless
steel AISI |
|
|
304, Hastelloy C276,
PFA, PTFE). |
|
|
|
|
9. |
Sample Recovery System |
|
|
|
|
|
Standard sample recovery
system includes supporting rack, drum, level switches, local instruments
(P1, |
|
|
T1), pump ADPE motor
driven, valves and local panel with push buttons and selectors for
local/remote |
|
|
control selection
and for pump start/stop. |
|
|
|